Overview of Self-Regulating Electric Heat Tracing Cable
Self-regulating electric heat tracing cable, also known as self-controlling electric heat tracing cable, is a new generation of the only constant-temperature strip heating product. It consists of high-molecular conductive carbon particles, two parallel bus wires, and an outer insulation layer. The PTC heating element has a high positive temperature coefficient of resistivity and is connected in parallel.
Features of Self-Regulating Electric Heat Tracing Cable
Self-regulating electric heat tracing cable can automatically limit the heating temperature and adjust the output power according to the temperature of the traced object. It can be cut arbitrarily or extended within a certain length. It allows multiple cross-overlaps without the risk of overheating and burning. It is easy to maintain and saves electrical energy.
Structure of Low Temperature Protective Electric Heat Tracing Cable

Polyolefin, flame-retardant PE, F46 insulation layer Conductive plastic layer Tinned soft copper wire
Product Model;
Low Temperature Protective Basic Type Product Model:DBY-J-Power-Voltage
Low Temperature Protective Flame-Retardant Type Product Model: DBY-JZ-Power-Voltage
Low Temperature Protective Anti-Corrosion Type Product Model: DBY-JF-Power-Voltage
Corresponding to DXW, DKW, DBW, DWK, DBR) and foreign models Raychem BTV, Tyco BSX, Bartec PSB series

Product Advantages;
1. Uniform temperature along the traced pipeline, safe and reliable
2. Low installation and operation costs, easy maintenance
3. Energy saving
4. Rapid startup during intermittent operation
5. Facilitates automated management
6. No environmental pollution
7. Suitable for complex pipelines and remote device tracing
8. Suitable for instrument box freeze protection
Technical Data;
1. Standard colors: black, gray (custom colors available for large quantities)
2. Temperature range: Maximum surface temperature 70°C±5°C at 10°C ambient, maximum withstand temperature 105°C
3. Minimum installation temperature: -60°C
4. Thermal stability: After 300 cycles between 10°C and 99°C, the heat output remains above 95%
5. Minimum bending radius: 25mm inner diameter of the cable
6. Insulation resistance: For a 100m cable at 75°C ambient, measured with a 2500VDC megohmmeter for 1 minute, the minimum insulation resistance (between conductor and shield) is 1200MΩ
7. Maximum single power supply length: 100m for 7*0.5 core, 120m for 19*0.32 core
8. Operating voltage: 12V, 24V, 36V, 110V, 220V, 380V
9. Output power at 10°C: 10W/m — 35W/m