Low Temperature Self-Regulating Explosion-Proof Electric Heat Tracing Cable




                                                             Overview of Self-Regulating Electric Heat Tracing Cable


    Self-regulating electric heat tracing cable, also known as self-controlled electric heat tracing cable, is a new generation of the only strip-shaped constant temperature electric heating product. It is composed of polymer conductive carbon particles, two parallel bus wires, and an insulating layer. The resistivity of its PTC heating element has a high positive temperature coefficient and is connected in parallel.


                                                             Features of Self-Regulating Electric Heat Tracing Cable


    Self-regulating electric heat tracing cable can automatically limit the heating temperature and adjust the output power according to the temperature of the traced object; it can be cut arbitrarily or extended within a certain length; it allows multiple overlaps without risk of overheating and burnout; it is easy to maintain and saves electricity.


                                                             Structure of Low Temperature Protective Electric Heat Tracing Cable


  

 ① Tinned soft copper conductor

  ② PTC fluoropolymer core tape (heating layer)

  ③ Perfluoro F46 insulation layer

  ④ Metal shielding layer (tinned copper wire or aluminum-magnesium alloy wire) 



                                                          Product Model;


                                    Low Temperature Explosion-Proof Product Model:DBY-P-Power-Voltage

                                 Low Temperature Explosion-Proof Flame Retardant Product Model: DBY-PZ-Power-Voltage


                                    Low Temperature Explosion-Proof Anti-Corrosion Product Model: DBY-PF-Power-Voltage


  Low Temperature Type: DBY (DXW, DKW, DBW, DWK, DBR) corresponds to foreign models Raychem BTV, Tyco BSX, Bartec PSB series.

 




Technical Data;

  1. Standard Color: Silver

   2. Temperature Range: Maximum surface temperature 70°C±5°C at 10°C ambient, maximum withstand temperature 105°C

   3. Minimum Installation Temperature: -60°C

   4. Thermal Stability: After 300 cycles between 10°C and 99°C, the heat output of the cable remains above 95%

   5. Minimum Bending Radius: 25mm inner diameter of the cable

   6. Insulation Resistance: For a 100m cable at 75°C ambient, measured with a 2500VDC megohmmeter for 1 minute, the insulation resistance (between conductor and shield) is at least 1200MΩ

   7. Maximum Single Power Supply Length: 100m for 7X0.5 core, 120m for 19X0.32 core



   Operating Voltage: 12V 24V 36V 110V 220V 380V 420V

   Output Power at 10°C: 10W/m 15W/m 25W/m 35W/m

   Explosion-Proof Mark: ExeIIT4, ExeIIT6



Technical Advantages;

   1. Uniform temperature along the traced pipeline, safe and reliable

   2. Low installation and operating costs, easy maintenance

   3. Energy saving

   4. Fast start-up during intermittent operation

   5. Easy for automated management